DLU32 - Elevator Traffic Analyzer
The Smallest in the World


NEWS:
The new DLU32 is now available. This unit uses USB to connect to your laptop, is about the size of a multi-meter and weighs in at 500 grams. Making this the most portable & independent Elevator Data Logger system anywhere. Plug up to 4 units into a PC or Laptop for a total of 128 channels.

SOFTWARE:

PRICING:
Contact us for pricing and delivery:
info@appliedmicros.com.au


DLU32 Data Logger units

Introducing the DLU32 Elevator Traffic Measurement & Analysis System.

As a Traffic Analysis system, the Data Logger is connected to the landing call indicators (and optionally the out of service signals) for a lift group. The Logger is then set up to log these signals for typically 1 week. This produces 7 logged data files on the Laptop which are taken back to the office for repeated analysis producing reports and/or data files for a spreadsheet or a word processor.

As a Diagnostic Tool, the Data Logger can connected to several lift controller signals and set up to log for whatever period is required, usually long enough to "catch" the fault being chased. This also produces logged data files (1 for each day) which can be analyzed either on the laptop or back in the office. This miscellaneous signal analysis allows the operator to define up to 19 Named Functions made up of from an arbitrary combination of actual data logger inputs ORed, ANDed and XORed together. These Named Functions are then reported on along with a timing diagram for each. This allows complex signal patterns to be searched for. Once the fault is "caught", further analysis can provide mode detailed information about what happened just before and after the fault. An analysis based on a user defined state-machine can also be performed to detect invalid signal sequences.

Of course, a logging for both Traffic Analysis and Diagnostics can be done simultaneously as the DLU32 stores all input changes to 1/10 second resolution to disk.

DLU32 SPECIFICATIONS

HARDWARE
Number of Inputs 32 per unit (up to 128)
Type of Inputs Optically Isolated (+ and -)
AC and DC signals supported YES
Negative DC signals supported YES
Input Threshold 9 Volts
Input Debouncing Software Selectable
Protection Mains Proof
Scanning Rate 200 Scans/sec

LOGGER SOFTWARE
Building and Logging Information Concise & Intuitive Windows forms
Minimum Logging Period 1 Minute
Maximum Logging Period 24 Hours
Maximum Number Logging Days 99
Programmable Input Polarity Landing Calls AND Out of Service
Input Map window YES
Import Settings YES
Resolution 1/10 second

ANALYZER SOFTWARE
Building and Logging Information Read from the Data File
Retrospective Analysis YES
Analyse a specific time zone YES
Analyse a specific set of floors YES
Minimum Analysis Period 1 Minute
Maximum Analysis Period Full Length of Logging
Maximum Number of Intervals 480
Interval Sizes 5, 10, 15, 20, 30, 60 min
Short Event Filter YES
Early Cancellation Correction YES
Long Event Count in All Reports YES

REPORTS
Report Output Screen, Printer, Save As Rich Text or Plain Text, Copy as TAB separated Rich Text, Copy WMF graphs
Day Summary Report YES
Interval Report YES
Landing Report YES
Duration Distribution Reports Every Second to 400 Seconds
Distribution Graphs YES
Performance Graphs YES

If you have any questions, please e-mail us:
info@appliedmicros.com.au


For all other Elevator Equipment see
Alphasoft Pty Limited

Home